Complaint ID 105311 — Public Copy

Report generated May 5, 2025 11:01 PM.

On this Page

Status: Approved/Closed

Complaint Received
September 25, 2023 8:30 AM
Assigned Office
Air Protection Branch
Complaint Closed
October 12, 2023 8:56 AM
Review Comments
[Not entered]

Nature of Complaint

Odor complaint

Primary Concern
Air Quality Control
Secondary Concern
[Not entered]

Complaint Location

Location of Complaint
125 Governor Treutlen Drive Rincon, GA 31326
City of Complaint
Rincon
County of Complaint
Effingham County

Source

Source Name
DRTA America
Facility ID Number
[Not entered]

Source Contact

Contact Name
John Myers
Source Address
125 Governor Treutlen Drive
Rincon, Georgia  31326

Actions

Initial Investigation Report

3‑Oct‑2023 by Sonakshi Kumar

For the complaint investigation, I met Mr. John Myers, Plant Manager of DRT America, Rincon GA. He had explained earlier as well as during the inspection about what went wrong. There was a man-way gasket(Picture attached) failure on TK804 (Picture attached) which prompted the operators to transfer the material to another storage tank. However, due to the location of the release, until TK804 could be emptied, it continued to release material into the concrete secondary containment area (Picture attached). The facility estimates about 500 gallons of the material to have been released. DRT America is still undergoing investigation; however, they believe that it was the corroded gasket (picture attached) which caused the spills. Also, he mentioned that as the temperature crosses 75 F, the turpentine smells start to spread across larger areas.

Attachments

(Attachments may not be available for complaints resolved before April 2018. Please note that not every complaint has attachments.)

None.